General
Topology Double-conversion online
Configuration Tower
Part Number 9EA03AA61101000
Color Black
Rating (VA/Watts) 30 kVA/24 kW
Efficiency
Up to 98% High-efficiency mode, Up to 92% Double-conversion


Mouseover graph for detailed efficiency values

* These efficiencies are for guidance only. Actual unit and system efficiencies will vary based on site design/conditions and environmental parameters *
Efficiency Graph Footer
UPS Bypass Automatic on overload or UPS failure
Dimensions (H x W x D, inches) 53.5 x 20.9 x 31.5
Dimensions (H x W x D, mm) 1360 x 530 x 800
Weight (kg) 476
Weight (lbs) 1049
Electrical Input
Connection Hardwired - see manual for terminal block layout
Hardwired - example layout only
Input Cord Hardwired
Input Voltage Range -15%, +20% from nominal (208V) at 100% load without depleting battery
Nominal Voltage 208V
Operating Frequency 50/60 Hz (40 to 72 Hz)
Input Power Factor >0.99 typical
Input Current Distortion 5% THD
Electrical Output
Nominal Voltage 208/220, 3/4 wire
Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change, < 20 ms response time
Output Receptacles Hardwired - see manual for terminal block layout
Hardwired - example layout only
Overload Capacity 150% for 40 ms / 125% for 30 seconds / 110% for 10 min
Battery

Runtime
(minutes)
Load (watts)
Mouseover graph for detailed runtime values


Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.
Battery Management ABM (Cyclic) or float
Battery Type 9Ah, sealed, lead-acid, maintenance-free
Battery Replacement Field-replaceable
Internal Batteries Yes has internal batteries, please note you cannot add EBCs
Communications
User Interface Graphical LCD with blue backlight
LEDs (4) LEDs for notice and alarm
Audible Alarms Yes
Communication Ports (1) RS-232, (1) REPO
Communications Slot (2) Mini-slot communication bays
Power Management Software Eaton Intelligent Power Software Suite CD (included)
Environmental & Standards
Audible Noise 64 dBA at 1 meter (noise less room) typical
Operating Temperature 0ºC (32ºF) to +30ºC (86ºF); Batteries recommended max. +25ºC (77ºF)
Safety markings UL60950 , EN55022/EN55024
EMC Markings IEC 62040-5
Markings UL, cUL
Storage Temperature -25ºC (-13ºF) to +55ºC (131ºF) without batteries; +15ºC (59ºF) to +25ºC (77ºF) with batteries
Relative Humidity 5 –95%, non-condensing
Altitude 1000m at +30°C (86ºF)