Eaton 9E 30 KVA UPS with Batteries and Bypass System
Uninterruptible Power Supply
Eaton 9E 30 KVA UPS Single Feed with Internal Batteries and Internal Maintenance Bypass System
| Eaton 9E 30 KVA UPS with Batteries and Bypass System | |
|---|---|
| General | |
| Topology | Double-conversion online |
| Configuration | Tower |
| Part Number | 9EA03AA61101000 |
| Color | Black |
| Rating (VA/Watts) | 30 kVA/24 kW |
| Efficiency | |
| Up to 98% High-efficiency mode, Up to 92% Double-conversion Mouseover graph for detailed efficiency values * These efficiencies are for guidance only. Actual unit and system efficiencies will vary based on site design/conditions and environmental parameters * |
|
| Efficiency Graph Footer | |
| UPS Bypass | Automatic on overload or UPS failure |
| Dimensions (H x W x D, inches) | 53.5 x 20.9 x 31.5 |
| Dimensions (H x W x D, mm) | 1360 x 530 x 800 |
| Weight (kg) | 476 |
| Weight (lbs) | 1049 |
| Electrical Input | |
| Connection | Hardwired - see manual for terminal block layout![]() |
| Input Cord | Hardwired |
| Input Voltage Range | -15%, +20% from nominal (208V) at 100% load without depleting battery |
| Nominal Voltage | 208V |
| Operating Frequency | 50/60 Hz (40 to 72 Hz) |
| Input Power Factor | >0.99 typical |
| Input Current Distortion | 5% THD |
| Electrical Output | |
| Nominal Voltage | 208/220, 3/4 wire |
| Output voltage regulation | ±1% Static; ±5% dynamic at 100% resistive load change, < 20 ms response time |
| Output Receptacles | Hardwired - see manual for terminal block layout![]() |
| Overload Capacity | 150% for 40 ms / 125% for 30 seconds / 110% for 10 min |
| Battery | |
|
Runtime
(minutes) Load (watts)
Mouseover graph for detailed runtime values
Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.
|
|
| Battery Management | ABM (Cyclic) or float |
| Battery Type | 9Ah, sealed, lead-acid, maintenance-free |
| Battery Replacement | Field-replaceable |
| Internal Batteries | Yes has internal batteries, please note you cannot add EBCs |
| Communications | |
| User Interface | Graphical LCD with blue backlight |
| LEDs | (4) LEDs for notice and alarm |
| Audible Alarms | Yes |
| Communication Ports | (1) RS-232, (1) REPO |
| Communications Slot | (2) Mini-slot communication bays |
| Power Management Software | Eaton Intelligent Power Software Suite CD (included) |
| Environmental & Standards | |
| Audible Noise | 64 dBA at 1 meter (noise less room) typical |
| Operating Temperature | 0ºC (32ºF) to +30ºC (86ºF); Batteries recommended max. +25ºC (77ºF) |
| Safety markings | UL60950 , EN55022/EN55024 |
| EMC Markings | IEC 62040-5 |
| Markings | UL, cUL |
| Storage Temperature | -25ºC (-13ºF) to +55ºC (131ºF) without batteries; +15ºC (59ºF) to +25ºC (77ºF) with batteries |
| Relative Humidity | 5 –95%, non-condensing |
| Altitude | 1000m at +30°C (86ºF) |