Eaton 5P 3000RT Tower UPS Technical Specifications
Enterprise class battery backup for network closets and small data centers

3000 VA / 2700W, 2U, 120V
The Eaton 5P is available in space saving 1U and 2U rackmount configurations.
| Eaton 5P 3000RT Tower UPS Technical Specifications | |
|---|---|
| General | |
| Topology | Line-interactive |
| Configuration | Rack/Tower |
| Color | Black |
| Rating (VA/Watts) | 3000/2700 |
| Diagnostics | Full system self-test at power up |
| Efficiency | up to 99%
Mouseover graph for detailed efficiency values |
| UPS Bypass | EHBPL3000R-PDU1U (optional) |
| Dimensions (H x W x D, inches) | 3.4 x 17.4 x 20.6 |
| Dimensions (H x W x D, mm) | 86 x 441 x 647 |
| Weight (kg) | 40 |
| Weight (lbs) | 87 |
| Warranty | 3 years on electronics, 3 years on batteries with registration |
| Rail Kit Included | Tower stands and 4-post rail kit included |
| Contents (Ships with the following items) |
5P3000RT Four-post rail kit User manual CD Tower pedestals Intelligent Power Software Suite CD Quick start guide RS-232 serial cable USB cable Phillips head screw driver |
| Electrical Input | |
| Connection | NEMA L5-30P![]() |
| Input Cord | 10 ft |
| Input Voltage Range | 89–151 Vac (adjustable to 70–153 Vac) |
| Nominal Voltage | 120 Vac (adjustable to 100/120/127 Vac) |
| Frequency | 50/60 Hz (auto-sensing) |
| Frequency Range | 47–70 Hz (50 Hz system), 56.5–70 Hz (60 Hz system), 40 Hz in low-sensitivity mode |
| Input Power Factor | 0.9 |
| Electrical Output | |
| Output Receptacles | (1) L5-30R![]() (6) 5-20R ![]() |
| On Utility Voltage Regulation | 102–132 Vac |
| On Battery Voltage Regulation | -10%, +6% of nominal |
| Output Frequency | 50/60 Hz ±0.1 % (autosensing) |
| Transfer Time | 1–4 ms typical |
| Load Segments | Group 1: (2) 5-20R outlets; Group 2: (2) 5-20R outlets |
| Battery | |
|
Runtime
(minutes) Load (watts)
Mouseover graph for detailed runtime values
Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.
|
|
| Battery Management | ABM® technology and temperature-compensated charging method (user selectable), automatic battery test, deep discharge protection, automatic recognition of extended battery modules (EBMs) |
| Battery Type | 12V/7.2 Ah; sealed, lead-acid; maintenance free |
| Battery Replacement | Hot-swappable internal batteries |
| Start On Battery | Allows start of UPS without utility power |
| Communications | |
| User Interface | LCD graphical display |
| LEDs | Load protected, on battery and fault |
| Communication Ports | 1 USB HID compliant port + 1 RS232 serial port and relay contacts (USB and RS232 ports cannot be used simultaneously) |
| Communications Card Slots | 1 slot for ConnectUPS-MS network management card |
| Power Management Software | Eaton Intelligent Power Software Suite CD (included) |
| Environmental & Standards | |
| Heat Dissipation (BTU) | Line: 305, Battery: 2047 |
| Audible Noise | <45 dBA |
| Operating Temperature | 0°C–40°C (32°F–104°F) |
| Performance - Safety - EMC | UL1778; UL497A; cUL |
| Safety markings | UL, cUL |
| EMC Markings | FCC Part 15 subpart B Class A |
| Storage Temperature | -15°C–50°C (5°F–122°F) |
| Relative Humidity | 20–95% non-condensing |
| Altitude | Up to 10,000 ft (3000m) without de-rating |