Eaton 5P 1000R Tower UPS Technical Specifications
Enterprise class battery backup for network closets and small data centers
![]()
1000 VA / 770W, 120V
| Eaton 5P 1000R Tower UPS Technical Specifications | |
|---|---|
| General | |
| Topology | Line-interactive |
| Configuration | Rackmount/Wallmount |
| Color | Black and silver |
| Rating (VA/Watts) | 1000/770 |
| Diagnostics | Full system self-test at power up |
| Efficiency | up to 97% |
| Dimensions (H x W x D, inches) | 1.7 (1U) x 17.2 x 20.0 |
| Dimensions (H x W x D, mm) | 43.2 x 438 x 509 |
| Weight (kg) | 14.72 |
| Weight (lbs) | 32.5 |
| Warranty | 3 years on electronics, 3 years on batteries with registration |
| Rail Kit Included | 4-post rail kit |
| Remote Emergency Power off (REPO) | ROO/RPO: Rear terminal block connector for remote on/off and power off |
| Contents (Ships with the following items) |
5P UPS User manual CD Intelligent Power Software Suite CD Quick start guide USB cable RS-232 serial cable 4-post rail kit ears |
| Electrical Input | |
| Connection | NEMA 5-15P![]() |
| Input Cord | 6 feet (1.8 meters) |
| Input Voltage Range | 89–151 Vac (adjustable to 70–153 Vac) |
| Nominal Voltage | 120 Vac (adjustable to 100/120/125Vac) |
| Frequency | 50/60 Hz (auto-sensing) |
| Frequency Range | 47–70 Hz (50 Hz system), 56.5–70 Hz (60 Hz system), 40-70 Hz in low-sensitivity mode |
| Electrical Output | |
| Nominal Voltage | 120V default (100/120/125V) |
| Output Receptacles | (5) NEMA 5-15R![]() |
| On Utility Voltage Regulation | 102–132 Vac |
| On Battery Voltage Regulation | -10%, +6% of nominal |
| Output Frequency | 50/60 Hz ±0.1 % (autosensing) |
| Load Segments | Group 1: (2) 5-15R outlets; Group 2: (1) 5-15R outlet |
| Battery | |
|
Runtime
(minutes) Load (watts)
Mouseover graph for detailed runtime values
Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.
|
|
| Battery Description | Sealed, lead-acid; maintenance free |
| Battery Management | ABM technology; 3-stage charging extends battery service life by 50% and provides advance warning for battery replacement |
| Battery Type | Sealed, lead-acid; maintenance free |
| Battery Replacement | Hot-swappable internal batteries |
| Extended Battery Capability | None |
| Start On Battery | Allows start of UPS without utility power (First time start must be on AC power) |
| Communications | |
| User Interface | LCD graphical display |
| LEDs | Load protected, on battery and fault |
| Communication Ports | RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included |
| Communications Card Slots | One slot; Network Card-MS is optional |
| Power Management Software | Eaton Intelligent Power Software Suite CD (included) |
| Environmental & Standards | |
| RoHS Compliance | Yes |
| Heat Dissipation (BTU) | Line: 106, Battery: 500 |
| Audible Noise | <45 dBA at 1 meter |
| Operating Temperature | 0 to 35°C (32°F to 95°F) |
| Performance - Safety - EMC | UL 1778, UL497A |
| Safety markings | cULus, CE |
| EMC Markings | IEC 62040-2 C1-C2 / EN 55024 / CISPR22 Class B / FCC part 15 Class B |
| Storage Temperature | -15°C – 40°C (5°F – 104°F) |
| Relative Humidity | 0–90% non-condensing |
| Altitude | Up to 10,000 ft (3000m) without de-rating |


